Estimating lumbar spine foraminal disc measurements using ultrasound and X-ray imaging through advanced image annotation, processing, and mathematical modeling during chiropractic traction procedures: A feasibility study

Why This Matters

Lumbar spine imaging is typically static, which limits the ability to observe how spinal dimensions change while a mechanical procedure is being applied. Ultrasound offers real-time imaging, but differences between ultrasound and X-ray measurements make direct comparison difficult.

This feasibility study explored a method for aligning measurements from X-ray and ultrasound so lumbar foraminal and disc-related dimensions could be estimated before and during graded chiropractic traction. The approach may provide a framework for studying real-time mechanical changes in the lumbar spine without relying solely on static imaging.

Importantly, this was a proof-of-concept study in healthy adults without a history of low back pain. It demonstrates measurement feasibility and biomechanical behavior, not diagnostic accuracy or treatment effectiveness in symptomatic patients.

What the Research Found

Fifteen healthy adults—8 men and 7 women—underwent a standardized chiropractic traction protocol. X-rays were obtained before the procedure, while ultrasound measurements were collected both before and during traction at L3-L4, L4-L5, and L5-S1.

Traction was progressively applied at 1.8 kg, 3.6 kg, 5.4 kg, and 11.3 kg. The researchers used geometric scaling and extrapolation methods to help reconcile measurements obtained from the two imaging modalities.

KEY POINTS

  • Lumbar spinal measurements increased during progressive traction. Measures including height and area showed consistent increases as traction force increased, demonstrating measurable elongation under loading.
  • Changes were evaluated across multiple lower lumbar levels. Ultrasound measurements were obtained at L3-L4, L4-L5, and L5-S1 before and during the traction procedure.
  • The method combined static and real-time imaging information. Pre-procedure X-ray measurements were integrated with ultrasound measurements obtained during traction using scaling and extrapolation techniques.
  • Real-time ultrasound captured mechanical changes during the procedure. The approach allowed spinal dimensions to be assessed while graded traction forces were actively applied.
  • The findings establish feasibility rather than clinical effectiveness. All 15 participants were healthy and had no history of low back pain, so the results cannot establish diagnostic or therapeutic benefit in patients with lumbar disorders.

Clinical Takeaways

    • Recognize that lumbar anatomy is mechanically dynamic. Foraminal and disc-related measurements changed during progressively applied traction rather than remaining fixed at their pre-procedure dimensions.
    • Interpret static imaging within its limitations. A conventional X-ray represents anatomy under a particular static condition and does not demonstrate the dimensional changes observed while traction is being applied.
    • Consider real-time imaging as a research tool for spinal biomechanics. Ultrasound permitted repeated measurements during the procedure and may help investigators characterize mechanical responses that static imaging cannot capture.
    • Avoid translating these findings into treatment-effectiveness claims. The study evaluated measurement methodology and biomechanical responses in healthy volunteers, not pain, function, neurologic outcomes, or treatment response in symptomatic patients.
    • Watch for validation in clinical populations. Further research would be needed to determine whether these measurement methods are reliable and clinically useful in patients with lumbar spine disorders.

Where Collaborative Spine Care May Support This

For clinicians using chiropractic traction or other mechanically directed conservative approaches, this research provides a potential method for studying how lumbar spinal dimensions change during an applied procedure. At present, its relevance is primarily biomechanical and investigational because the study involved healthy volunteers and did not evaluate clinical outcomes.

Reference

Bhagi C, Gudavalli MR, Kruse RA, Cox JM. Estimating lumbar spine foraminal disc measurements using ultrasound and X-ray imaging through advanced image annotation, processing, and mathematical modeling during chiropractic traction procedures: A feasibility study. Bioengineering (Basel, Switzerland). 2026;13(3). doi:10.3390/bioengineering13030330.

VIEW FULL ABSTRACT

View full abstract: https://pubmed.ncbi.nlm.nih.gov/41899861/